Application progress of partial pressure of end tidal carbon dioxide in hemodynamic management |
Zeng Xue-ping, Sun Feng, Xu Jun |
Department of Emergency, Peking Union Medical College Hospital, Beijing 100730, China |
|
|
Abstract Hemodynamic management is an important part of the circulatory function monitoring in critically ill patient. However, traditional hemodynamic monitoring methods are invasive and expensive, which are not suitable for emergency patients. The partial pressure of end tidal carbon dioxide (PetCO2) is simple, noninvasive and real time. It not only reflects the basal metabolism of the body, but also reflects the circulation and ventilation conditions. It is a novel approach of hemodynamic monitoring. This article describes the application progress of PetCO2 in hemodynamic management, including the physiological basis of PetCO2 and its use in shock and cardiopulmonary resuscitation, PetCO2 and fluid responsiveness, volumetric carbon dioxide and fluid responsiveness.
|
|
Corresponding Authors:
Xu Jun, E-mail: xujunfree@126.com
|
|
|
|
[1]Suess EM, Pinsky MR. Hemodynamic Monitoring for the Evaluation and Treatment of Shock: What Is the Current State of the Art[J]. Semin Respir Crit Care Med, 2015, 36(6):890-898.
[2]Saugel B, Huber W, Nierhaus A, et al. Advanced Hemodynamic Management in Patients with Septic Shock[J]. Bio Med Res Int, 2016, 2016:8 268 569.
[3]Mackenzie DC, Noble VE. Assessing volume status and fluid responsiveness in the emergency department[J]. Clin Exp Emerg Med, 2014, 1(2):67-77.
[4]Sakka SG. Hemodynamic Monitoring in the Critically Ill Patient-Current Status and Perspective[J]. Front Med(Lausanne), 2015, 2:44.
[5]Siobal MS. Monitoring Exhaled Carbon Dioxide[J]. Respir Care, 2016, 61(10):1397-1416.
[6]Steedman DJ, Robertson CE. Measurement of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation[J]. Arch Emerg Med, 1990, 7(3):129-134.
[7]Shih TH, Huang CE, Chen CL, et al. Correlation Between Changes in End-Tidal Carbon Dioxide Concentration and Cardiac Output During Inferior Vena Cava Clamping and Unclamping in Living-donor Liver Transplantation[J]. Transplant Proc, 2016, 48(4):1077-1079.
[8]汪建平,陈孝平,秦新裕,等. 外科学[M]. 第8版. 北京:人民卫生出版社, 2013:30.
[9]Joseph B, Haider A, Ibraheem K, et al. Revitalizing Vital Signs: The Role of Delta Shock Index[J]. SHOCK, 2016, 46 (3 Suppl 1):50-54.
[10]Jin X, Weil MH, Tang W, et al. End-tidal carbon dioxide as a noninvasive indicator of cardiac index during circulatory shock[J]. Crit Care Med, 2000, 28(7):2415-2419.
[11]Kheng CP, Rahman NH. The use of end-tidal carbon dioxide monitoring in patients with hypotension in the emergency department[J]. Int J Emerg Med, 2012, 5(1):31.
[12]Link MS, Berkow LC, Kudenchuk PJ, et al. Part 7: Adult Advanced Cardiovascular Life Support[J]. Circulation, 2015, 132(18 suppl 2):S444-464.
[13]Ryu SJ, Lee SJ, Park CH, et al. Arterial pressure, end-tidal carbon dioxide, and central venous oxygen saturation in reflecting compression depth[J]. Acta Anaesthesiol Scand, 2016, 60(7):1012-1023.
[14]Einav S, Bromiker R, Weiniger CF, et al. Mathematical Modeling for Prediction of Survival From Resuscitation Based on Computerized Continuous Capnography: Proof of Concept[J]. Acad Emerg Med, 2011, 18(5):468-475.[15]Zuercher M, Hilwig RW, Ranger-Moore J, et al. Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrest[J]. Crit Care Med, 2010, 38(4):1141-1146.
[16]Pantazopoulos C, Xanthos T, Pantazopoulos I, et al. A Review of Carbon Dioxide Monitoring During Adult Cardiopulmonary Resuscitation[J]. Heart Lung Circ, 2015, 24(11):1053-1061.
[17]Sandroni C, De Santis P, D′ Arrigo S. Capnography during cardiac arrest[J]. Resuscitation, 2018, 132:73-77.
[18]Pokorna M, Necas E, Kratochvíl J, et al. A Sudden Increase in Partial Pressure End-Tidal Carbon Dioxide (PETCO2) at the Moment of Return of Spontaneous Circulation[J]. J Emerg Med, 2010, 38(5):614-621.
[19]Maurer C, Wagner JY, Schmid RM, et al. Assessment of volume status and fluid responsiveness in the emergency department: a systematic approach[J]. Med Klin Intensivmed Notfmed, 2017, 112(4):326-333.
[20]Jacquet Lagrèze M, Baudin F, David JS, et al. End tidal carbon dioxide variation after a 100 and a 500 ml fluid challenge to assess fluid responsiveness[J]. Ann Intensive Care, 2016, 6(1):37.
[21]赵华,王小亭,刘大为. 呼气末二氧化碳分压在感染性休克患者容量反应性评估中的作用[J]. 中华内科杂志, 2014, 53(5):359-362
[22]姚滔,吴伟芳,郑霞,等. 呼气末二氧化碳分压联合被动抬腿试验对心脏术后休克患者容量反应性评估的价值[J]. 中华危重病急救医学, 2016, 28(5):391-395.
[23]柳彦涛,李叶宁,周文静,等. 呼气末二氧化碳分压评估重症急性胰腺炎患者液体复苏的价值[J]. 中国基层医药, 2016, 23(13):2016-2019.
[24]Xiaoting W, Hua Z, Dawei L, et al. Changes in end-tidal CO2 could predict fluid responsiveness in the passive leg raising test but not in the mini-fluid challenge test: A prospective and observational study[J]. J Crit Care, 2015, 30(5):1061-1066.
[25]Monnet X, Bataille A, Magalhaes E, et al. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test[J].Intensive Care Med, 2013, 39(1):93-100.
[26]Monge García MI, Gil Cano A, Gracia Romero M, et al. Noninvasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver[J]. Ann Intensive Care, 2012, 2(1):9.
[27]臧芝栋,严洁,许红阳,等. 呼气末二氧化碳分压的变化对感染性休克机械通气患者容量反应性的预测价值[J].中华内科杂志, 2013, 52(8):646-650.
[28]Toupin F, Clairoux A, Deschamps A, et al. Assessment of fluid responsiveness with endtidal carbon dioxide using a simplified passive leg raising maneuver: a prospective observational study[J]. Can J Anaesth, 2016, 63(9):1033-1041.
[29]Suarez Sipmann F, Bohm SH, Tusman G. Volumetric capnography:the time has come[J]. Curr Opin Crit Care, 2014, 20(3):333-339.
[30]Blanch L, Romero PV, Lucangelo U. Volumetric capnography in the mechanically ventilated patient[J]. Minerva Anestesiol, 2006, 72(6):577-585.
[31]Tusman G, Suarez-Sipmann F, Paez G, et al. States of low pulmonary blood flow can be detected non-invasively at the bedside measuring alveolar dead space[J]. J Clin Monit Comput, 2012, 26(3):183-190.
[32]Young A, Marik PE, Sibole S, et al. Changes in End-Tidal Carbon Dioxide and Volumetric Carbon Dioxide as Predictors of Volume Responsiveness in Hemodynamically Unstable Patients[J]. J Cardiothorac Vasc Anesth, 2013, 27(4):681-684. |
|
|
|